Development of a novel real-time method to study the erythrocytic life cycle of Plasmodium falciparum using Quartz Crystal Microbalances. Entwicklung einer neuen Echtzeit-Methode zur Untersuchung des erytrozytärer Lebenszyklus von Plasmodium falcipar

Bustos Cruz, Rosa Elena

Development of a novel real-time method to study the erythrocytic life cycle of Plasmodium falciparum using Quartz Crystal Microbalances. Entwicklung einer neuen Echtzeit-Methode zur Untersuchung des erytrozytärer Lebenszyklus von Plasmodium falcipar

Previous studies carried out by the Biosensor Research Group of the Institute of Clinical
and Experimental Transfusion Medicine at the Tübingen University had successfully
demonstrated determination of various blood types through the interaction of
erythrocytes with immobilised antibodies on a QCM. These studies have opened the
possibility to test new applications of this technique for the study of infectious diseases.
In our case, studies of the erythrocyte life cycle of P. falciparum, particularly during the last
six hours preceding the merozoite release and studies related to reinfection of by
merozoites were the focus of our investigation.
Release of malaria parasites of P. falciparum from infected erythrocyte at the end of their
asexual erythrocyte cycle occurs approximately every 48 hours, asynchronously in parasite
culture and synchronously in vivo. This process is poorly studied due to: (I) merozoite
release is a very short event (<60 S), (II) schizont stages have high sensitivity for culture
conditions like pH, medium, osmotic pressure, gas atmosphere and temperature. (III)
Schizont conditions are not easy to maintain under the miscrocope, making
miscroscopical real time observation of the release difficult.
The aim of the presented project was to study the release of Plasmodium falciparum
merozoites from erythrocytes with the QCM sensor technique. In this way, the frequency
shift due to the change of mass associated to the merozoite release and, on a second
QCM, the reinfection of healthy erythrocytes are monitored in real time. Our QCM
experiments included the following stages: (I) Adaptation and optimisation of the
immobilisation of biological layers to capture the erythrocytes on the quartz. (II)
Optimisation of parasite culture conditions in a QCM chamber. (III) Observation of the
frequency signal both for infected and non-infected erythrocytes samples and correlation
of the signal with the release of merozoites. (IV) Reinfection of healthy erythrocytes on a
second quartz within one QCM system. (V) Test of inhibition of merozoite release and
reinfection by antimalarial compounds.